Journal of Clinical Oncology  
Search for:
Limit by:
  Browse by Topic or Issue
Home Search/Browse Subscriptions PDA Services My JCO Customer Service

Journal of Clinical Oncology, 2007 ASCO Annual Meeting Proceedings (Post-Meeting Edition).
Vol 25, No 18S (June 20 Supplement), 2007: 19676
© 2007 American Society of Clinical Oncology
This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Download to citation manager
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Van Erps, J.
Right arrow Articles by Abraham, I.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Van Erps, J.
Right arrow Articles by Abraham, I.

Abstract

Promoting evidence-based management of anemia in cancer patients: Background and scientific validation of RESPOND, a web-based clinical decision support system

J. Van Erps, M. Aapro, K. MacDonald, P. Soubeyran, M. Muenzberg, R. Dunlop, C. Eeckhout, H. Warrinnier, M. van Well and I. Abraham

Algemeen Stedelijk Ziekenhuis Aalst, Aalst, Belgium; Clinique de Genolier, Genolier, Switzerland; Matrix45, Earlysville, VA; Institut Bergonie, Bordeaux, France; F. Hoffmann-La Roche, Basel, Switzerland; InferMed, London, United Kingdom; Roche S.A., Brussels, Belgium

19676

Background: The 2006 European Organisation for Research and Treatment of Cancer (EORTC) guidelines for erythropoietic proteins in cancer-related anemia provide the most up-to-date assessment of the evidence base. To promote clinicians’ adoption of evidence- based (EB) practice guidelines (EBPGs), it is critical to bring guidelines to the point of care. RESPOND is an EB clinical decision support system (CDSS) based on the EORTC guidelines. CDSSs are seldom validated. We describe the methodologies of two studies being conducted to validate RESPOND. Methods. Study 1: descriptive design - accuracy and content validity. Five experts are asked to rate the accuracy of algorithms derived from the guidelines; the objective being an intraclass correlation coefficient =0.90 for each of 27 algorithmic sets. Study 2: hybrid matched pre-post design - concurrent and discriminant validity. Two patient cohorts (n=33 each) matched by type of cancer and similarity of chemotherapy regimen ie, sample 1 (4 months prospective data after RESPOND [post]) and sample 2 (4 months retrospective data prior to RESPOND [pre]) were used to test concurrent validity (congruence scores [CS] of sample 1) and discriminant validity (difference between sample 2 and sample 1 CS). A score is calculated for each patient to quantify the extent to which treatment and outcomes are congruent with the EORTC EBPG. Table 1. Calculation of the congruence score ESA, erythropoiesis-stimulating agent; Hb, hemoglobin, Q1W, once weekly, Q3W, once every three weeks Conclusions. These studies will provide the necessary validation for RESPOND as an evidence-based clinical support tool.


View this table:
[in this window]
[in a new window]

 
 


Author Disclosure
Employment or Leadership Bonsultant or Advisory Stock Ownership Honoraria Research Expert Testimony Other Remuneration

Roche Amgen, Baxter Oncology, Chugai Pharma USA, Johnson & Johnson, Roche, Schering AG Amgen, Johnson & Johnson, Ortho Biotech, Roche, Schering AG Roche






About
JCO
 Editorial
Roster
 Advertising
Information
 Librarians &
Institutions
 Rights &
Permissions

Copyright © 2007 by the American Society of Clinical Oncology, Online ISSN: 1527-7755. Print ISSN: 0732-183X
Terms and Conditions of Use
HighWire Press HighWire Press™ assists in the publication of JCO Online